(Click here for the Current
Derating Curve chart)
Metric Dimensions are shown in mm (Shown in green)
Copyright 2002, Portage Electric Products, Incorporated, All rights reserved.

Standard Marking System
(Click Here)
|
 |
A creep-action thermostat/thermal protector with highest contact rating
of all Model A Series thermostats. Available with gold diffused contacts
for use in low voltage/low current applications, or with fine silver contacts
for 120 VAC applications.
Features

- Conductive bimetal construction; the bimetallic element carries the
circuit current.
- Creep action device; slow make/slow break switching action.
No built-in differential between the opening and closing temperature.
- Case electrically alive; insulating sleeving is available.
Preset calibration temperature; not adjustable in the field.
- Available to open circuit on rise of temperature (normally closed),
Models A2 and AA2, or close circuit on rise of temperature (normally
open), Models A2R and AA2R.
- Available with gold diffused, fine silver contacts for use in low
voltage/low current applications.
- Available with same end termination, Models A2 and A2R; or opposite
end termination, Model AA2 and AA2R.
- Available with factory applied lead wires.
Models -A2 and -AA2 are without gold diffused contacts
Contact Ratings

- 5 amps/120 volts AC resistive
- 4 amps/120 volts AC inductive Please consult with our Sales
Please consult with our Sales Engineers for suggested contact ratings
when applied on DC loads.
(Click here for complete contact rating information)
Calibration Temperature Range

- Available with nominal calibration temperatures from 5° C to 200°
C.
(Printable Version)
(Download .PDF)

Click the banner for Adobe
Acrobat Reader

|